| Mass total |
17.15 |
kg |
| Mass Dust Analyzer |
4.64 |
kg |
| Mass Main Electronics |
6.8 |
kg |
| Mass Preamplifier Box |
3.75 |
kg |
| Mass High Rate Detector |
1.05 |
kg |
| Mass Thermal Blanket |
0.91 |
kg |
| Power consumption (sleep, HRD off) |
10.15 |
W |
| Power consumption (HRD on) |
11.70 |
W |
| Power consumption of Replacement Heater |
11.25 |
W |
| Power consumption Dectontamination Heater |
8.85 |
W |
| Voltage |
30 |
V |
| Temperature (Main Electronics, operating) |
-15 - +40 |
°C |
| Temperature (HRD, operating) |
-25 - +40 |
°C |
| Radiation Hardness |
100 |
krad |
| Data interface |
1553 |
Bus |
| Data rate Housekeeping |
19 |
bps |
| Data rate Science |
524 |
bps |
| Articulation range |
0 - 270 |
° |
| Target Diameter (IID) |
0.41 |
m |
| Target Diameter (CAT) |
0.16 |
m |
| Field-of-View (IID) |
+/-45 |
° |
| Field-of-View (CAT) |
+/-28 |
° |
| Dimensions |
0.70x0.45x0.80 |
m^3 |
| Sensitivity Particle Charge @20 km/s |
1e-15 |
C |
| Sensitivity Particle speed @10e-13 kg |
1 |
km/s |
| Sensitivity Particle mass @5 km/s |
10e-16 |
kg |
| Mass resolution |
20 - 50 |
dalton |
| Counting rate limit DA/HRD |
1/10000 |
s^-1 |